Support #397
customer called with issues in setting up the Mylaps X2 loop settings
Status: | Resolved | Start date: | 09/23/2018 | |
---|---|---|---|---|
Priority: | Normal | Due date: | ||
Assignee: | % Done: | 0% | ||
Category: | X2 decoder | Spent time: | 1.00 h | |
Target version: | Customer needs to fix |
Description
LQMA called with Mylaps X2 loop setup issues
History
#1
Updated by Walter Pate almost 4 years ago
- Status changed from New to Feedback
LQMA had issues getting the loop to pickup transponders.
I went into the LQMA computer with TeamViewer and checked the Network ip settings,
I pinged the decoder and MyLaps webserver
checked the Moscore X2 settings
Tried to pass the transponders behind the decoder and they did not register.
We did find thet the minimum lap time was set to 8 seconds, it should have been 6.2!
Then had the customer pass a transponder across the loop outside
We found that they started top register after setting the squelch to a -60db
The decoder showed an error saying that there was a Loop problem!
They could not get the transponders to register at the back of the decoder in the tower
Moscore is now showing that the MyLaps X2 Competition Karting transponders are registering now
Awaiting feedback
#2
Updated by Walter Pate over 1 year ago
- Status changed from Feedback to Resolved
no further reports